Extended EGT thermocouple wire for the #2, 3, and 4 cylinder exhaust gas temperature probes. Printed heat shrink labels and placed them before and after the splice. Used Wirefly crimp splices, testing each splice with a gentle pull on each TC wire. Applied heat to shrink the splices. separated TC from signal wires at firewall. and bound TC wires together with plastic ties.